Assessment Year | 2023 |
---|---|
Principal Product | polyhydroxyalkanoates (PHAs) |
NAICS | 325212: Synthetic Rubber Manufacturing |
SIC | 2822: Synthetic Rubber (Vulcanizable Elastomers) |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
190,000
ft2
|
Annual Production | 11,490,891
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $303,360 | 4,137,588 |
kWh
|
$0.073 |
Natural Gas | $102,958 | 10,429 |
MMBtu
|
$9.87 |
TOTAL YEARLY COSTS | $406,318 | |||
RECOMMENDED SAVINGS* | $178,965 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,890 | $1,850 |
$21,790
298,499
kWh
|
- | $(-2,900.0) | |
02 | 2.2625: Chill water to the highest temperature possible | $3,384 | $400 |
$3,384
46,355
kWh
|
- | - | |
03 | 2.6218: Turn off equipment when not in use | $4,632 | $867 |
$4,632
63,449
kWh
|
- | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $13,705 | $17,982 |
$13,705
187,746
kWh
|
- | - | |
05 | 2.3212: Optimize plant power factor | $1,025 | $5,227 | - | $1,025 | - | |
06 | 2.9114: Use solar heat to make electricty | $137,329 | $2,565,299 |
$137,329
1,873,049
kWh
|
- | - | |
TOTAL RECOMMENDED | $178,965 | $2,591,625 |
$180,840
2,469,098
kWh
|
$1,025 | $(-2,900.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs