Assessment Year | 2023 |
---|---|
Principal Product | School Buses |
NAICS | 336211: Motor Vehicle Body Manufacturing |
SIC | 3713: Truck and Bus Bodies |
Sales Range | greater than $500 M |
# of Employees | 1,200 |
Plant Area |
1,000,000
ft2
|
Annual Production | 6,727
units
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,522,135 | 21,337,881 |
kWh
|
$0.071 |
Natural Gas | $933,982 | 103,204 |
MMBtu
|
$9.05 |
TOTAL YEARLY COSTS | $2,456,117 | |||
RECOMMENDED SAVINGS* | $405,892 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $246,074 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $64,657 | $1,850 |
$67,557
965,109
kWh
|
$(-2,900.0) | |
02 | 2.6218: Turn off equipment when not in use | $104,725 | $13,000 |
$104,725
1,475,000
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $73,640 | $23,680 |
$73,640
1,037,184
kWh
|
- | |
04 | 2.6218: Turn off equipment when not in use | $3,052 | $3,250 |
$3,052
42,981
kWh
|
- | |
05 | 2.9114: Use solar heat to make electricty | $159,818 | $4,611,930 |
$159,818
2,240,394
kWh
|
- | |
TOTAL RECOMMENDED | $405,892 | $4,653,710 |
$408,792
5,760,668
kWh
|
$(-2,900.0) | ||
TOTAL IMPLEMENTED | $246,074 | $41,780 |
$248,974
3,520,274
kWh
|
$(-2,900.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs