Assessment Year | 2020 |
---|---|
Principal Product | Cubed/Flaked Ice Making Machines |
NAICS | 333241: Food Product Machinery Manufacturing |
SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
Sales Range | $100 M to 500M |
# of Employees | 523 |
Plant Area |
220,000
ft2
|
Annual Production | 78,000
units
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $675,857 | 7,719,000 |
kWh
|
$0.088 | |
Natural Gas | $50,482 | 8,217 |
MMBtu
|
$6.14 | |
Waste Disposal Costs | |||||
Water Usage | $281,257 | 29,451 |
Tgal
|
$9.55 | |
TOTAL YEARLY COSTS | $1,007,596 | ||||
RECOMMENDED SAVINGS* | $331,826 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $35,845 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Usage Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $20,227 | $1,450 |
$20,227
229,857
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,618 | $2,500 |
$15,618
177,478
kWh
|
- | - | |
03 | 2.7141: Lower light fixtures in high ceiling areas | $14,945 | $4,781 |
$14,945
169,828
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $50,179 | $71,763 |
$50,179
570,220
kWh
|
- | - | |
05 | 3.4151: Minimize water usage | $3,202 | $5,700 |
$1,712
19,455
kWh
|
- |
$1,490
-
Tgal
|
|
06 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $113,048 | $690,000 |
$164,736
1,872,000
kWh
|
$(-51,688.4)
-
MMBtu
|
- | |
07 | 2.9114: Use solar heat to make electricty | $114,607 | $699,103 |
$114,607
1,308,931
kWh
|
- | - | |
TOTAL RECOMMENDED | $331,826 | $1,475,297 |
$382,025
4,347,768
kWh
|
$(-51,688.4)
-
MMBtu
|
$1,490
-
Tgal
|
||
TOTAL IMPLEMENTED | $35,845 | $3,950 |
$35,845
407,335
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs