Assessment Year | 2020 |
---|---|
Principal Product | Refrigerators, Freezers, Ice Bins |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $100 M to 500M |
# of Employees | 663 |
Plant Area |
275,875
ft2
|
Annual Production | 49,200
pieces
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $427,615 | 5,382,900 |
kWh
|
$0.079 |
Natural Gas | $34,070 | 6,782 |
MMBtu
|
$5.02 |
TOTAL YEARLY COSTS | $461,685 | |||
RECOMMENDED SAVINGS* | $161,206 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,237 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $9,332 | $1,450 |
$9,332
118,121
kWh
|
- | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $7,493 | $2,000 | - | $7,493 | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,247 | $2,500 |
$6,247
79,070
kWh
|
- | - | |
04 | 2.7135: Install occupancy sensors | $6,947 | $3,377 |
$6,947
87,939
kWh
|
- | - | |
05 | 2.2524: Avoid cooling of process streams or materials that must subsequently be heated | $6,583 | $6,500 |
$4,434
55,811
kWh
|
- |
$2,150
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,453 | $25,191 |
$18,453
233,588
kWh
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $659 | $939 |
$659
8,296
kWh
|
- | - | |
08 | 2.9114: Use solar heat to make electricty | $105,492 | $696,247 |
$105,492
1,327,952
kWh
|
- | - | |
TOTAL RECOMMENDED | $161,206 | $738,204 |
$151,563
1,910,777
kWh
|
$7,493 |
$2,150
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,237 | $4,889 |
$16,237
205,487
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs