| Assessment Year | 2018 |
|---|---|
| Principal Product | Exterior Doors |
| NAICS | 332321: Metal Window and Door Manufacturing |
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $50 M to 100M |
| # of Employees | 240 |
| Plant Area |
284,000
ft2
|
| Annual Production | 416,292
units
|
| Production Hrs. Annual | 3,120
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $280,085 | 2,448,040 |
kWh
|
$0.11 |
| Natural Gas | $18,993 | 1,333 |
MMBtu
|
$14.25 |
| TOTAL YEARLY COSTS | $299,078 | |||
| RECOMMENDED SAVINGS* | $76,133 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,834 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $20,126 | $10,000 |
$20,126
182,965
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $16,834 | $10,400 |
$16,834
153,037
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,029 | $18,819 |
$22,029
192,238
kWh
|
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $311 | $912 |
$311
2,832
kWh
|
|
| 05 | 2.9114: Use solar heat to make electricty | $16,833 | $137,000 |
$16,833
147,110
kWh
|
|
| TOTAL RECOMMENDED | $76,133 | $177,131 |
$76,133
678,182
kWh
|
||
| TOTAL IMPLEMENTED | $16,834 | $10,400 |
$16,834
153,037
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs