| Assessment Year | 2017 |
|---|---|
| Principal Product | Aircraft part repair |
| NAICS | 332813: Electroplating, Plating, Polishing, Anodizing, and Coloring |
| SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 105 |
| Plant Area |
50,000
ft2
|
| Annual Production | 6,000
units
|
| Production Hrs. Annual | 4,200
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $195,319 | 1,713,285 |
kWh
|
$0.11 |
| Natural Gas | $1,501 | 166 |
MMBtu
|
$9.03 |
| TOTAL YEARLY COSTS | $196,820 | |||
| RECOMMENDED SAVINGS* | $171,036 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $109,444 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $89,452 | $5,000 |
$89,452
813,918
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,992 | $10,805 |
$19,992
173,089
kWh
|
|
| 03 | 2.2437: Recover waste heat from equipment | $1,259 | $2,654 |
$1,259
11,295
kWh
|
|
| 04 | 2.7233: Use properly designed and sized hvac equipment | $8,249 | $18,040 |
$8,249
74,994
kWh
|
|
| 05 | 2.9113: Use solar heat for heat | $52,084 | $187,502 |
$52,084
456,889
kWh
|
|
| TOTAL RECOMMENDED | $171,036 | $224,001 |
$171,036
1,530,185
kWh
|
||
| TOTAL IMPLEMENTED | $109,444 | $15,805 |
$109,444
987,007
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs