Assessment Year | 2017 |
---|---|
Principal Product | Cotton yarn |
NAICS | 313110: Fiber, Yarn, and Thread Mills |
SIC | 2299: Textile goods, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 104 |
Plant Area |
254,000
ft2
|
Annual Production | 75,000,000
lb
|
Production Hrs. Annual | 8,424
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,642,319 | 54,001,574 |
kWh
|
$0.030 |
TOTAL YEARLY COSTS | $1,642,319 | |||
RECOMMENDED SAVINGS* | $105,356 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,361 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $2,820 | $250 |
$2,820
94,000
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,671 | $250 |
$2,671
89,042
kWh
|
|
03 | 2.2625: Chill water to the highest temperature possible | $1,890 | $180 |
$1,890
63,011
kWh
|
|
04 | 2.7211: Clean and maintain refrigerant condensers and towers | $42,468 | $8,000 |
$42,468
1,682,273
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $38,980 | $127,113 |
$38,980
1,299,326
kWh
|
|
06 | 2.2511: Insulate bare equipment | $16,527 | $106,785 |
$16,527
550,930
kWh
|
|
TOTAL RECOMMENDED | $105,356 | $242,578 |
$105,356
3,778,582
kWh
|
||
TOTAL IMPLEMENTED | $46,361 | $127,793 |
$46,361
1,545,379
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs