Assessment Year | 2011 |
---|---|
Principal Product | Plastic Parts/Assemblies |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 400 |
Plant Area |
220,000
ft2
|
Annual Production | 24,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $846,495 | 22,101,687 |
kWh
|
$0.038 |
Electricity Demand | $306,910 | 30,839 |
kW-mo/yr
|
$9.95 |
Electricity Fees | $92,702 | - |
|
- |
Natural Gas | $2,912 | 176 |
MMBtu
|
$16.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $82,614 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,008 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,060 | $2,500 |
$2,247
58,675
kWh
|
$813
-
kW-mo/yr
|
|
02 | 2.7122: Disconnect ballasts | $635 | $885 |
$466
12,166
kWh
|
$169
-
kW-mo/yr
|
|
03 | 2.7134: Use photocell controls | $197 | $285 |
$197
5,131
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $582 | $1,450 |
$288
7,528
kWh
|
$294
-
kW-mo/yr
|
|
05 | 2.4314: Use synthetic lubricant | $55,071 | - |
$33,336
870,400
kWh
|
$21,735
-
kW-mo/yr
|
|
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,318 | $8,163 |
$14,318
373,854
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,257 | $12,880 |
$3,126
81,627
kWh
|
$1,131
-
kW-mo/yr
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,494 | $14,600 |
$3,300
86,160
kWh
|
$1,194
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $82,614 | $40,763 |
$57,278
1,495,541
kWh
|
$25,336
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $12,008 | $30,265 |
$8,870
231,593
kWh
|
$3,138
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs