Assessment Year | 2007 |
---|---|
Principal Product | Rubber Backed Floor Mats |
NAICS | 314110: Carpet and Rug Mills |
SIC | 2273: Carpets and Rugs |
Sales Range | $50 M to 100M |
# of Employees | 240 |
Plant Area |
190,000
ft2
|
Annual Production | 41,400
thousand feet
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $100,306 | 2,865,872 |
kWh
|
$0.035 |
Electricity Demand | $109,609 | 6,172 |
kW-mo/yr
|
$17.76 |
Natural Gas | $473,220 | 53,676 |
MMBtu
|
$8.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $114,705 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $25,825 | $10,000 |
$13,685
391,008
kWh
|
$12,140
-
kW-mo/yr
|
- | - | - | |
02 | 2.2212: Use minimum safe oven ventilation | $5,955 | $6,000 |
$178
5,088
kWh
|
$141
-
kW-mo/yr
|
$5,636
-
MMBtu
|
- | - | |
03 | 2.6218: Turn off equipment when not in use | $7,976 | - | - | - |
$7,976
-
MMBtu
|
- | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,908 | - | - | - |
$4,808
-
MMBtu
|
- | $(-900.0) | |
05 | 2.2163: Use minimum steam operating pressure | $17,020 | - | - | - |
$17,020
-
MMBtu
|
- | - | |
06 | 2.1241: Reduce excessive boiler blowdown | $1,288 | $3,975 | - | - |
$1,050
-
MMBtu
|
$238
-
Tgal
|
- | |
07 | 2.7224: Reduce space conditioning during non-working hours | $2,338 | $2,250 |
$2,338
66,792
kWh
|
- | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $39,896 | $127,725 |
$21,141
604,032
kWh
|
$18,755
-
kW-mo/yr
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,159 | $17,436 |
$4,323
123,552
kWh
|
$3,836
-
kW-mo/yr
|
- | - | - | |
10 | 2.2511: Insulate bare equipment | $2,340 | $2,004 | - | - |
$2,340
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $114,705 | $169,390 |
$41,665
1,190,472
kWh
|
$34,872
-
kW-mo/yr
|
$38,830
-
MMBtu
|
$238
-
Tgal
|
$(-900.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs