| Assessment Year | 2007 |
|---|---|
| Principal Product | Beverage Packaging |
| NAICS | 322212: Folding Paperboard Box Manufacturing |
| SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
| Sales Range | $100 M to 500M |
| # of Employees | 240 |
| Plant Area |
500,000
ft2
|
| Annual Production | 1,150,000,000
pieces
|
| Production Hrs. Annual | 7,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,188,252 | 18,737,151 |
kWh
|
$0.063 |
| Natural Gas | $1,129,611 | 132,802 |
MMBtu
|
$8.51 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $367,743 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $86,975 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $48,543 | $3,750 |
$48,542
1,085,008
kWh
|
$1
-
kW-mo/yr
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,785 | $6,280 |
$7,784
174,000
kWh
|
$1
-
kW-mo/yr
|
- | |
| 03 | 2.6218: Turn off equipment when not in use | $9,709 | $600 |
$9,709
217,000
kWh
|
- | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $19,640 | $51,790 |
$19,639
439,350
kWh
|
$1
-
kW-mo/yr
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,676 | $5,730 |
$10,675
238,630
kWh
|
$1
-
kW-mo/yr
|
- | |
| 06 | 2.2437: Recover waste heat from equipment | $239,330 | $464,160 | - | - |
$239,330
-
MMBtu
|
|
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,938 | $54,630 |
$20,937
467,784
kWh
|
$1
-
kW-mo/yr
|
- | |
| 08 | 2.7135: Install occupancy sensors | $11,122 | $22,750 |
$11,121
248,874
kWh
|
$1
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $367,743 | $609,690 |
$128,407
2,870,646
kWh
|
$6
-
kW-mo/yr
|
$239,330
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $86,975 | $65,260 |
$86,972
1,943,792
kWh
|
$3
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs