| Assessment Year | 2006 |
|---|---|
| Principal Product | Woolen and Worsted Finishing |
| NAICS | 313210: Broadwoven Fabric Mills |
| SIC | 2231: Broadwoven Fabric Mills, Wool (Including Dyeing and Finishing) |
| Sales Range | $10 M to 50M |
| # of Employees | 230 |
| Plant Area |
665,000
ft2
|
| Annual Production | 6,000
thousand feet
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,399,921 | 21,466,498 |
kWh
|
$0.065 |
| Natural Gas | $361,104 | 35,081 |
MMBtu
|
$10.29 |
| Fuel Oil #6 | $847,096 | 135,861 |
MMBtu
|
$6.24 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $205,667 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #6 Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $14,828 | - | - | - | $14,828 | - | |
| 02 | 2.1221: Replace obsolete burners with more efficient ones | $95,828 | $140,000 | - |
$95,828
-
MMBtu
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $3,150 | $4,150 |
$3,150
57,897
kWh
|
- | - | - | |
| 04 | 2.7135: Install occupancy sensors | $13,107 | $1,500 |
$13,107
240,935
kWh
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $78,754 | $182,180 |
$72,600
1,334,551
kWh
|
- | - | $6,154 | |
| TOTAL RECOMMENDED | $205,667 | $327,830 |
$88,857
1,633,383
kWh
|
$95,828
-
MMBtu
|
$14,828 | $6,154 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs