Assessment Year | 2006 |
---|---|
Principal Product | carpet |
NAICS | 314110: Carpet and Rug Mills |
SIC | 2273: Carpets and Rugs |
Sales Range | $10 M to 50M |
# of Employees | 656 |
Plant Area |
1,282,000
ft2
|
Annual Production | 745,480
thousand feet
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $765,703 | 275,444,570 |
kWh
|
$0.003 |
Electricity Demand | $190,187 | 62,976 |
kW-mo/yr
|
$3.02 |
Electricity Fees | $68,175 | - |
|
- |
Natural Gas | $5,688,394 | 622,717 |
MMBtu
|
$9.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $271,308 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,760 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $10,700 | $19,575 |
$10,700
384,100
kWh
|
- | - | - | - | - | |
02 | 2.7122: Disconnect ballasts | $4,943 | $2,350 |
$4,305
154,300
kWh
|
$638
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $44,039 | $127,200 |
$38,470
1,378,800
kWh
|
$5,569
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.2314: Replace heat treating oven with more efficient unit | $101,891 | $132,900 | - | - | - |
$101,891
-
MMBtu
|
- | - | |
05 | 2.8112: Combine utility meters | $13,828 | - | - | - | $13,828 | - | - | - | |
06 | 2.8114: Change rate schedules or other changes in utility service | $20,760 | $8,200 | - | - | - | - | $20,760 | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,968 | $1,280 |
$1,714
61,442
kWh
|
$254
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,457 | $4,600 |
$8,236
295,000
kWh
|
$1,221
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $21,450 | $15,000 | - | - | - |
$13,090
-
MMBtu
|
- | $8,360 | |
10 | 2.2191: Substitute hot process fluids for steam | $42,272 | $85,000 | - | - | - |
$42,272
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $271,308 | $396,105 |
$63,425
2,273,642
kWh
|
$7,682
-
kW-mo/yr
|
$13,828 |
$157,253
-
MMBtu
|
$20,760 | $8,360 | ||
TOTAL IMPLEMENTED | $20,760 | $8,200 | - | - | - | - | $20,760 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs