Assessment Year 2005
Principal Product Turbine Blades
NAICS 336412: Aircraft Engine and Engine Parts Manufacturing
SIC 3724: Aircraft Engines and Engine Parts
Sales Range $50
M
to 100
M
# of Employees 328
Plant Area 235,000
ft2
Annual Production 200,000
pieces
Production Hrs. Annual 7,488
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,175,768 24,799,764
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $128,330 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,230

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.2511: Insulate bare equipment $22,100 $2,782 $22,100
476,508
kWh
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,230 $2,150 $1,230
26,422
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $24,900 $52,200 $24,900
536,260
kWh
04 2.7142: Utilize higher efficiency lamps and/or ballasts $13,300 $23,431 $13,300
285,650
kWh
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,600 $2,613 $1,600
34,499
kWh
06 2.4133: Use most efficient type of electric motors $28,900 $135,800 $28,900
622,458
kWh
07 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $26,000 $59,670 $26,000
560,000
kWh
08 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $10,300 $13,870 $10,300
222,250
kWh
TOTAL RECOMMENDED $128,330 $292,516 $128,330
2,764,047
kWh
TOTAL IMPLEMENTED $1,230 $2,150 $1,230
26,422
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs