| Assessment Year | 2005 |
|---|---|
| Principal Product | Fiberglass Bathtubs |
| NAICS | 326191: Plastics Plumbing Fixture Manufacturing |
| SIC | 3088: Plastics Plumbing Fixtures |
| Sales Range | $5 M to 10M |
| # of Employees | 50 |
| Plant Area |
109,065
ft2
|
| Annual Production | 32,700
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $30,975 | 861,120 |
kWh
|
$0.036 |
| Electricity Demand | $40,267 | 49,109 |
kW-mo/yr
|
$0.82 |
| Electricity Fees | $6,195 | - |
|
- |
| Natural Gas | $106,034 | 11,937 |
MMBtu
|
$8.88 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $119,330 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $310 | $253 |
$67
2,190
kWh
|
$39
-
kW-mo/yr
|
- | - | - | $204 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,451 | $3,470 |
$425
13,800
kWh
|
$1,026
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,375 | $5,705 |
$649
21,076
kWh
|
$1,726
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.7122: Disconnect ballasts | $1,400 | $700 |
$410
13,321
kWh
|
$990
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 2.8112: Combine utility meters | $4,682 | $7,000 | - | - | - | - | $4,682 | - | |
| 06 | 2.8114: Change rate schedules or other changes in utility service | $23,800 | - | - | - | - | $23,800 | - | - | |
| 07 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $11,117 | $10,000 |
$3,265
106,000
kWh
|
$7,852
-
kW-mo/yr
|
- | - | - | - | |
| 08 | 2.5194: Redesign process | $74,195 | $46,000 |
$(-2,464.0)
(-80,000)
kWh
|
$(-15,456.0)
-
kW-mo/yr
|
$92,115
-
MMBtu
|
- | - | - | |
| TOTAL RECOMMENDED | $119,330 | $73,128 |
$2,352
76,387
kWh
|
$(-3,823.0)
-
kW-mo/yr
|
$92,115
-
MMBtu
|
$23,800 | $4,682 | $204 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs