Assessment Year 2005
Principal Product Plastic Film
NAICS 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $50
M
to 100
M
# of Employees 92
Plant Area 125,000
ft2
Annual Production 35,000,000
lb
Production Hrs. Annual 8,568
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $458,658 21,925,000
kWh
Electricity Demand $581,530 50,573
kW-mo/yr
Electricity Fees $81,069 -
Natural Gas $61,057 5,505
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $86,747 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $47,987

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $12,040 $32,725 $6,450
230,465
kWh
$5,590
-
kW-mo/yr
- -
02 2.7134: Use photocell controls $7,520 $32,480 $5,840
208,716
kWh
$1,680
-
kW-mo/yr
- -
03 2.7224: Reduce space conditioning during non-working hours $72 - $5
178
kWh
- - $67
-
MMBtu
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $775 $500 $491
17,540
kWh
$284
-
kW-mo/yr
- -
05 2.6218: Turn off equipment when not in use $2,820 $500 $1,750
62,455
kWh
$1,070
-
kW-mo/yr
- -
06 2.2628: Utilize a less expensive cooling method $1,780 $7,500 $1,780
63,453
kWh
- - -
07 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $35,100 $15,000 - $35,100
-
kW-mo/yr
- -
08 2.7232: Replace existing hvac unit with high efficiency model $11,320 $10,000 $5,490
152,627
kWh
$5,830
-
kW-mo/yr
- -
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,950 $6,600 $2,950
81,850
kWh
- - -
10 2.8112: Combine utility meters $12,370 - - - $12,370 -
TOTAL RECOMMENDED $86,747 $105,305 $24,756
817,284
kWh
$49,554
-
kW-mo/yr
$12,370 $67
-
MMBtu
TOTAL IMPLEMENTED $47,987 $48,225 $6,946
248,183
kWh
$40,974
-
kW-mo/yr
- $67
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs