ITAC Assessment: GT0796
ITAC logo
ITAC Assessment: GT0796
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Door Mats
NAICS 314110: Carpet and Rug Mills
SIC 2273: Carpets and Rugs
Sales Range $10
M
to 50
M
# of Employees 61
Plant Area 88,075
ft2
Annual Production 11,057
thousand feet
Production Hrs. Annual 4,650
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $45,602 1,753,920
kWh
Electricity Demand $71,699 4,922
kW-mo/yr
Electricity Fees $16,307 -
Natural Gas $91,886 13,052
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $29,962 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,781

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.8112: Combine utility meters $4,508 $9,000 - - - $4,508
02 2.4231: Reduce the pressure of compressed air to the minimum required $895 $200 $373
14,334
kWh
$522
-
kW-mo/yr
- -
03 2.7221: Lower temperature during the winter season and vice-versa $835 - $152
5,838
kWh
- $683
-
MMBtu
-
04 2.7221: Lower temperature during the winter season and vice-versa $815 $500 $548
21,110
kWh
- $267
-
MMBtu
-
05 2.1113: Reduce combustion air flow to optimum $8,427 $1,750 - - $8,427
-
MMBtu
-
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,639 $9,925 $2,823
108,610
kWh
$2,816
-
kW-mo/yr
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $8,051 $50,551 $3,781
145,406
kWh
$4,270
-
kW-mo/yr
- -
08 2.7313: Recycle air for heating, ventilation and air conditioning $792 $1,910 - - $792
-
MMBtu
-
TOTAL RECOMMENDED $29,962 $73,836 $7,677
295,298
kWh
$7,608
-
kW-mo/yr
$10,169
-
MMBtu
$4,508
TOTAL IMPLEMENTED $9,781 $50,751 $4,306
165,578
kWh
$4,792
-
kW-mo/yr
$683
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs