Assessment Year 2004
Principal Product FLEXIBLE PACKAGING ROLL STOCK
NAICS 326112: Plastics Packaging Film and Sheet (including Laminated) Manufacturing
SIC 2671: Packaging Paper and Plastics Film, Coated and Laminated
Sales Range $10
M
to 50
M
# of Employees 85
Plant Area 70,000
ft2
Annual Production 13,000,000
lb
Production Hrs. Annual 6,336
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $232,792 3,731,365
kWh
Natural Gas $53,577 6,808
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,725 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,055

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2628: Utilize a less expensive cooling method $7,120 $5,800 $7,120
244,123
kWh
-
02 2.1331: Burn a less expensive grade of fuel $9,340 $2,000 $(-521.0)
(-17,844)
kWh
$9,861
-
MMBtu
03 2.1321: Replace fossil fuel equipment with electrical equipment $7,210 $3,000 $(-31,942.0)
(-1,093,493)
kWh
$39,152
-
MMBtu
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,280 $2,145 $1,280
43,864
kWh
-
05 2.7224: Reduce space conditioning during non-working hours $2,625 $200 $1,625
55,478
kWh
$1,000
-
MMBtu
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $540 $450 $540
18,344
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $610 $2,340 $610
20,985
kWh
-
TOTAL RECOMMENDED $28,725 $15,935 $(-21,288.0)
(-728,543)
kWh
$50,013
-
MMBtu
TOTAL IMPLEMENTED $5,055 $5,135 $4,055
138,671
kWh
$1,000
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs