| Assessment Year | 2003 |
|---|---|
| Principal Product | DECORATIVE PAPER |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 2754: Commercial Printing, Gravure |
| Sales Range | $10 M to 50M |
| # of Employees | 145 |
| Plant Area |
200,000
ft2
|
| Annual Production | 196,850
thousand feet
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $590,434 | 11,063,308 |
kWh
|
$0.053 |
| Natural Gas | $363,464 | 88,715 |
MMBtu
|
$4.10 |
| Fuel Oil #2 | $9,560 | 1,177 |
MMBtu
|
$8.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $105,026 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $53,534 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,720 | $47,268 |
$20,720
388,020
kWh
|
- | - | - | |
| 02 | 2.7492: Use proper thickness of insulation on building envelope | $9,072 | $12,000 |
$9,072
73,742
kWh
|
- | - | - | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $1,895 | $47,736 | n/a |
$1,895
35,496
kWh
|
- | - | - |
| 04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $14,438 | $31,350 | n/a |
$14,438
401,600
kWh
|
- | - | - |
| 05 | 2.3132: Recharge batteries on during off-peak demand periods | $322 | - | - |
$322
-
kW-mo/yr
|
- | - | |
| 06 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $28,386 | $12,140 | n/a |
$28,386
789,557
kWh
|
- | - | - |
| 07 | 2.2414: Use waste heat from hot flue gases to preheat | $6,773 | $6,150 | - | - |
$6,773
-
MMBtu
|
- | |
| 08 | 3.4116: Meter recycled water (to reduce sewer charges) | $23,420 | $1,850 | - | - | - |
$23,420
-
Tgal
|
|
| TOTAL RECOMMENDED | $105,026 | $158,494 |
$74,511
1,688,415
kWh
|
$322
-
kW-mo/yr
|
$6,773
-
MMBtu
|
$23,420
-
Tgal
|
||
| TOTAL IMPLEMENTED | $53,534 | $61,118 |
$29,792
461,762
kWh
|
$322
-
kW-mo/yr
|
- |
$23,420
-
Tgal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs