Assessment Year | 2003 |
---|---|
Principal Product | MOLDED PARTS |
NAICS | 327110: Pottery, Ceramics, and Plumbing Fixture Manufacturing |
SIC | 3261: Vitreous China Plumbing Fixtures and China and Earthenware Fittings and Bathroom Accessories |
Sales Range | $5 M to 10M |
# of Employees | 110 |
Plant Area |
9,600,000
ft2
|
Annual Production | 519,000,000
pieces
|
Production Hrs. Annual | 8,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $344,926 | 5,522,156 |
kWh
|
$0.062 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $108,182 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,279 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $267 | $100 |
$147
6,520
kWh
|
$102
-
kW-mo/yr
|
$18 | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $43,776 | $270,000 |
$22,464
993,454
kWh
|
$18,448
-
kW-mo/yr
|
$2,864 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $252 | $350 |
$139
6,141
kWh
|
$97
-
kW-mo/yr
|
$16 | |
04 | 2.4239: Eliminate or reduce compressed air usage | $1,740 | - |
$1,020
45,100
kWh
|
$720
-
kW-mo/yr
|
- | |
05 | 2.2511: Insulate bare equipment | $47,676 | $9,250 |
$1,033
36,700
kWh
|
$45,700
-
kW-mo/yr
|
$943 | |
06 | 2.4133: Use most efficient type of electric motors | $6,358 | $41,789 |
$2,593
114,746
kWh
|
$3,409
-
kW-mo/yr
|
$356 | |
07 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $7,662 | $1,500 |
$4,217
186,588
kWh
|
$2,944
-
kW-mo/yr
|
$501 | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $451 | $135 |
$171
7,565
kWh
|
$251
-
kW-mo/yr
|
$29 | |
TOTAL RECOMMENDED | $108,182 | $323,124 |
$31,784
1,396,814
kWh
|
$71,671
-
kW-mo/yr
|
$4,727 | ||
TOTAL IMPLEMENTED | $16,279 | $43,739 |
$8,116
359,095
kWh
|
$7,272
-
kW-mo/yr
|
$891 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs