Assessment Year | 2002 |
---|---|
Principal Product | Bottle Capping Machines |
NAICS |
n/a
|
SIC | 3565: Packaging Machinery |
Sales Range | $10 M to 50M |
# of Employees | 87 |
Plant Area |
69,460
ft2
|
Annual Production | 44
units
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,797 | 677,440 |
kWh
|
$0.060 |
Electricity Demand | $18,544 | 306 |
kW-mo/yr
|
$60.60 |
Electricity Fees | $2,472 | - |
|
- |
Natural Gas | $12,200 | 1,422 |
MMBtu
|
$8.58 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,924 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,924 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $15,773 | $1,400 |
$12,000
55,685
kWh
|
$3,773
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,487 | $15,062 |
$2,782
28,722
kWh
|
$1,705
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $710 | $400 |
$485
4,396
kWh
|
$225
-
kW-mo/yr
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $248 | $475 |
$248
2,345
kWh
|
- | - | |
05 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $706 | - | - | - |
$706
-
lb
|
|
TOTAL RECOMMENDED | $21,924 | $17,337 |
$15,515
91,148
kWh
|
$5,703
-
kW-mo/yr
|
$706
-
lb
|
||
TOTAL IMPLEMENTED | $21,924 | $17,337 |
$15,515
91,148
kWh
|
$5,703
-
kW-mo/yr
|
$706
-
lb
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs