Assessment Year | 2001 |
---|---|
Principal Product | Tapestry Products |
NAICS |
n/a
|
SIC | 2392: House furnishing, Except Curtains and Draperies |
Sales Range | $50 M to 100M |
# of Employees | 483 |
Plant Area |
372,000
ft2
|
Annual Production | 6,500,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $156,106 | 5,866,000 |
kWh
|
$0.027 |
Electricity Demand | $95,245 | 1,725 |
kW-mo/yr
|
$55.21 |
Electricity Fees | $97,747 | - |
|
- |
Natural Gas | $294,672 | 41,362 |
MMBtu
|
$7.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $141,559 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $141,559 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3512: De-energize excess transformer capacity | $21,103 | $60,000 |
$6,671
87,600
kWh
|
$4,793
-
kW-mo/yr
|
$9,639 | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $35,140 | $68,913 |
$29,489
708,596
kWh
|
$4,635
-
kW-mo/yr
|
$1,016 | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,660 | $825 |
$4,470
107,400
kWh
|
$1,024
-
kW-mo/yr
|
$166 | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,036 | $350 |
$818
19,650
kWh
|
$188
-
kW-mo/yr
|
$30 | - | - | |
05 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $76,655 | - | - | - | - |
$69,515
-
lb
|
$7,140 | |
06 | 2.4239: Eliminate or reduce compressed air usage | $1,965 | $1,418 |
$1,141
27,417
kWh
|
$767
-
kW-mo/yr
|
$57 | - | - | |
TOTAL RECOMMENDED | $141,559 | $131,506 |
$42,589
950,663
kWh
|
$11,407
-
kW-mo/yr
|
$10,908 |
$69,515
-
lb
|
$7,140 | ||
TOTAL IMPLEMENTED | $141,559 | $131,506 |
$42,589
950,663
kWh
|
$11,407
-
kW-mo/yr
|
$10,908 |
$69,515
-
lb
|
$7,140 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs