Assessment Year | 2001 |
---|---|
Principal Product | Speakers |
NAICS |
n/a
|
SIC | 3931: Musical Instruments |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
274,865
ft2
|
Annual Production | 150,500
pieces
|
Production Hrs. Annual | 2,200
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $248,921 | 6,274,267 |
kWh
|
$0.040 |
Electricity Demand | $162,106 | 19,902 |
kW-mo/yr
|
$8.15 |
Electricity Fees | $24,661 | - |
|
- |
Natural Gas | $96,327 | 11,085 |
MMBtu
|
$8.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $128,058 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,522 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3137: Use power during off-peak periods | $22,943 | - | - |
$22,943
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.3137: Use power during off-peak periods | $2,767 | - | - | - | $2,767 | - | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,175 | $200 |
$2,787
58,950
kWh
|
$2,098
-
kW-mo/yr
|
$290 | - | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,580 | $3,750 |
$4,516
108,000
kWh
|
$4,524
-
kW-mo/yr
|
$540 | - | - | - | |
05 | 2.3132: Recharge batteries on during off-peak demand periods | $2,350 | $840 | - |
$2,215
-
kW-mo/yr
|
$135 | - | - | - | |
06 | 3.5311: Recover and reuse waste material | $77,243 | $235,000 |
$(-3,279.0)
(-110,000)
kWh
|
$(-2,826.0)
-
kW-mo/yr
|
- |
$18,678
-
lb
|
- | $64,670 | |
07 | 3.5311: Recover and reuse waste material | $8,000 | $5,000 | - | - | - |
$18,678
-
lb
|
$(-10,678.0) | - | |
TOTAL RECOMMENDED | $128,058 | $244,790 |
$4,024
56,950
kWh
|
$28,954
-
kW-mo/yr
|
$3,732 |
$37,356
-
lb
|
$(-10,678.0) | $64,670 | ||
TOTAL IMPLEMENTED | $17,522 | $3,950 |
$7,303
166,950
kWh
|
$6,622
-
kW-mo/yr
|
$3,597 | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs