| Assessment Year | 2000 |
|---|---|
| Principal Product | Carpet Backing |
| NAICS |
n/a
|
| SIC | 2273: Carpets and Rugs |
| Sales Range | $100 M to 500M |
| # of Employees | 122 |
| Plant Area |
920,000
ft2
|
| Annual Production | 720,000,000
thousand feet
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $275,785 | 12,535,692 |
kWh
|
$0.022 |
| Electricity Demand | $108,068 | 7,219 |
kW-mo/yr
|
$14.97 |
| Electricity Fees | $109,701 | - |
|
- |
| Natural Gas | $732,216 | 168,636 |
MMBtu
|
$4.34 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $123,987 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $46,077 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,348 | $11,544 |
$1,638
74,466
kWh
|
$1,527
-
kW-mo/yr
|
$183 | - | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,800 | $32,760 |
$5,285
240,240
kWh
|
$4,902
-
kW-mo/yr
|
$613 | - | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,410 | - |
$4,410
126,071
kWh
|
- | - | - | - | - | |
| 04 | 2.8112: Combine utility meters | $2,640 | - | - | - | $2,640 | - | - | - | |
| 05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $30,230 | $43,056 | - | - | - | - | $(-1,500.0) | $31,730 | |
| 06 | 2.2212: Use minimum safe oven ventilation | $60,060 | $5,200 | - | - | - |
$60,060
-
MMBtu
|
- | - | |
| 07 | 2.4133: Use most efficient type of electric motors | $12,499 | $78,601 |
$12,499
336,887
kWh
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $123,987 | $171,161 |
$23,832
777,664
kWh
|
$6,429
-
kW-mo/yr
|
$3,436 |
$60,060
-
MMBtu
|
$(-1,500.0) | $31,730 | ||
| TOTAL IMPLEMENTED | $46,077 | $133,201 |
$14,137
411,353
kWh
|
$1,527
-
kW-mo/yr
|
$183 | - | $(-1,500.0) | $31,730 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs