Assessment Year 2000
Principal Product Lawnmowers
NAICS
n/a
SIC 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment
Sales Range $100
M
to 500
M
# of Employees 800
Plant Area 180,000
ft2
Annual Production 150,000
pieces
Production Hrs. Annual 4,000
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $358,139 12,758,793
kWh
Electricity Demand $357,370 32,937
kW-mo/yr
Electricity Fees $50,085 -
Natural Gas $191,073 61,063
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $359,777 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $59,142

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
01 4.454: Modify startup/shutdown times $96,627 - - $91,157
-
kW-mo/yr
$5,470 - - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $39,400 $152,830 $16,020
667,644
kWh
$21,150
-
kW-mo/yr
$2,230 - - -
03 2.4133: Use most efficient type of electric motors $7,416 $63,200 $3,060
120,164
kWh
$3,950
-
kW-mo/yr
$406 - - -
04 2.4231: Reduce the pressure of compressed air to the minimum required $12,800 - $5,254
218,933
kWh
$6,796
-
kW-mo/yr
$750 - - -
05 2.4239: Eliminate or reduce compressed air usage $26,280 $64,000 $6,903
287,515
kWh
$17,890
-
kW-mo/yr
$1,487 - - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,972 $1,050 $2,902
120,750
kWh
$1,788
-
kW-mo/yr
$282 - - -
07 2.8114: Change rate schedules or other changes in utility service $97,512 - - - - - - $97,512
08 3.5311: Recover and reuse waste material $14,770 $1,250 - - - $14,770
-
lb
- -
09 4.513: Re-arrange equipment layout to reduce labor costs $60,000 $120,000 - - - - $60,000 -
TOTAL RECOMMENDED $359,777 $402,330 $34,139
1,415,006
kWh
$142,731
-
kW-mo/yr
$10,625 $14,770
-
lb
$60,000 $97,512
TOTAL IMPLEMENTED $59,142 $155,130 $18,922
788,394
kWh
$22,938
-
kW-mo/yr
$2,512 $14,770
-
lb
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs