Assessment Year | 2000 |
---|---|
Principal Product | Egg Cartons and Egg Trays |
NAICS |
n/a
|
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 240 |
Plant Area |
343,500
ft2
|
Annual Production | 6,772,500,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $618,930 | 32,235,932 |
kWh
|
$0.019 |
Electricity Demand | $615,576 | 50,402 |
kW-mo/yr
|
$12.21 |
Electricity Fees | $125,319 | - |
|
- |
Natural Gas | $1,435,087 | 488,432 |
MMBtu
|
$2.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $240,713 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,162 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2692: Use outside cold water source as a supply of cooling water | $16,970 | $35,000 |
$8,387
436,694
kWh
|
$7,623
-
kW-mo/yr
|
$960 | - | - | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $5,567 | $56,336 |
$2,752
143,318
kWh
|
$2,500
-
kW-mo/yr
|
$315 | - | - | - | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $1,350 | $324 |
$670
34,584
kWh
|
$586
-
kW-mo/yr
|
$94 | - | - | - | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $13,915 | $29,000 |
$6,532
340,270
kWh
|
$6,595
-
kW-mo/yr
|
$788 | - | - | - | - | |
05 | 3.4151: Minimize water usage | $8,289 | $2,400 |
$709
36,928
kWh
|
$645
-
kW-mo/yr
|
$81 | - |
$6,854
-
Tgal
|
- | - | |
06 | 3.4111: Use closed cycle process to minimize waste water production | $34,271 | $19,000 | - | - | - | - |
$27,476
-
Tgal
|
- | $6,795 | |
07 | 3.4151: Minimize water usage | $26,306 | $7,850 |
$903
47,186
kWh
|
$820
-
kW-mo/yr
|
$104 | - |
$24,479
-
Tgal
|
- | - | |
08 | 4.423: Move product using mechanical means | $39,645 | $60,000 | - | - | - | - | - | $36,000 | $3,645 | |
09 | 2.2211: Use optimum temperature | $94,400 | - | - | - | - |
$94,400
-
MMBtu
|
- | - | - | |
TOTAL RECOMMENDED | $240,713 | $209,910 |
$19,953
1,038,980
kWh
|
$18,769
-
kW-mo/yr
|
$2,342 |
$94,400
-
MMBtu
|
$58,809
-
Tgal
|
$36,000 | $10,440 | ||
TOTAL IMPLEMENTED | $40,162 | $66,586 |
$4,364
227,432
kWh
|
$3,965
-
kW-mo/yr
|
$500 | - |
$31,333
-
Tgal
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs