| Assessment Year | 2000 |
|---|---|
| Principal Product | PVC Pipe And Vinyl Siding |
| NAICS |
n/a
|
| SIC | 3084: Plastics Pipe |
| Sales Range | $10 M to 50M |
| # of Employees | 255 |
| Plant Area |
983,000
ft2
|
| Annual Production | 51,983
ton
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $604,296 | 19,421,161 |
kWh
|
$0.031 |
| Electricity Demand | $188,279 | 15,669 |
kW-mo/yr
|
$12.02 |
| Electricity Fees | $47,865 | - |
|
- |
| Natural Gas | $5,429 | 878 |
MMBtu
|
$6.18 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $574,754 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | By-product Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $32,450 | - | n/a | - | - | - | - | $32,450 | - | - |
| 02 | 3.5112: Reprocess spent oils on site for re-use | $9,458 | $8,900 | n/a | - | - |
$2,552
-
gal
|
$(-300.0) | - | $7,206 | - |
| 03 | 4.441: Install automatic packing equipment | $72,000 | $112,000 | n/a | - | - | - | $72,000 | - | - | - |
| 04 | 4.451: Add additional production shift | $336,000 | $225,000 | n/a | - | - | - | - | - | - | $336,000 |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $1,495 | $2,000 | n/a |
$1,410
36,342
kWh
|
$85 | - | - | - | - | - |
| 06 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $82,231 | - | n/a |
$51,727
1,643,904
kWh
|
$3,104 | - | $27,400 | - | - | - |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,460 | $32,400 | n/a |
$6,094
201,641
kWh
|
$366 | - | - | - | - | - |
| 08 | 2.7111: Reduce illumination to minimum necessary levels | $16,070 | $61,209 | n/a |
$15,163
519,930
kWh
|
$907 | - | - | - | - | - |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,228 | - | n/a |
$1,158
35,756
kWh
|
$70 | - | - | - | - | - |
| 10 | 2.4133: Use most efficient type of electric motors | $17,362 | $72,500 | n/a |
$4,587
113,130
kWh
|
$275 | - | $12,500 | - | - | - |
| TOTAL RECOMMENDED | $574,754 | $514,009 |
$80,139
2,550,703
kWh
|
$4,807 |
$2,552
-
gal
|
$111,600 | $32,450 | $7,206 | $336,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | By-product Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs