Assessment Year | 1999 |
---|---|
Principal Product | Glass Panels |
NAICS |
n/a
|
SIC | 3211: Flat Glass |
Sales Range | $1 M to 5M |
# of Employees | 27 |
Plant Area |
140,000
ft2
|
Annual Production | 780,750
thousand feet
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $31,221 | 1,282,825 |
kWh
|
$0.024 |
Electricity Demand | $25,436 | 2,013 |
kW-mo/yr
|
$12.64 |
Electricity Fees | $3,616 | - |
|
- |
Natural Gas | $295,343 | 91,179 |
MMBtu
|
$3.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $115,130 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,148 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.4156: Use flow control valves on equipment to optimize water use | $3,081 | $500 | - | - |
$1,337
-
Tgal
|
- | - | $1,744 | - | |
02 | 3.5311: Recover and reuse waste material | $11,148 | - | - | - | - |
$11,148
-
lb
|
- | - | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $29,047 | $12,000 | - |
$29,047
-
MMBtu
|
- | - | - | - | - | |
04 | 2.2531: Re-size charging openings or add movable cover or door | $20,293 | $15,000 | - |
$20,293
-
MMBtu
|
- | - | - | - | - | |
05 | 4.424: Improve space comfort conditioning | $33,650 | $18,000 | - | - | - | - | - | - | $33,650 | |
06 | 2.8112: Combine utility meters | $292 | - | - | - | - | - | $292 | - | - | |
07 | 3.4156: Use flow control valves on equipment to optimize water use | $1,295 | $100 | - | - |
$945
-
Tgal
|
- | - | $350 | - | |
08 | 3.1191: Change procedures / equipment / operating conditions | $16,324 | $35,000 |
$2,507
78,253
kWh
|
- |
$5,103
-
Tgal
|
- | - | $8,714 | - | |
TOTAL RECOMMENDED | $115,130 | $80,600 |
$2,507
78,253
kWh
|
$49,340
-
MMBtu
|
$7,385
-
Tgal
|
$11,148
-
lb
|
$292 | $10,808 | $33,650 | ||
TOTAL IMPLEMENTED | $11,148 | - | - | - | - |
$11,148
-
lb
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs