Assessment Year | 1999 |
---|---|
Principal Product | Aggregate Stone |
NAICS |
n/a
|
SIC | 3281: Cut Stone and Stone Products |
Sales Range | $10 M to 50M |
# of Employees | 29 |
Plant Area |
2,178,000
ft2
|
Annual Production | 1,700,000
ton
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $84,023 | 3,501,172 |
kWh
|
$0.024 |
Electricity Demand | $173,892 | 12,977 |
kW-mo/yr
|
$13.40 |
Electricity Fees | $15,475 | - |
|
- |
Fuel Oil #2 | $245,000 | 49,000 |
MMBtu
|
$5.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $275,450 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Fuel Oil #2 Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4131: Size electric motors for peak operating efficiency | $9,897 | $5,660 |
$3,593
118,992
kWh
|
$5,744
-
kW-mo/yr
|
$560 | - | - | - | - | |
02 | 3.5111: Filter and reuse hydraulic oil | $2,625 | $3,500 | - | - | - | - | - | - | $2,625 | |
03 | 3.7311: Maintain machines to reduce leaks | $6,500 | $5,000 | - | - | - | - | - | - | $6,500 | |
04 | 4.445: Install equipment to move product | $213,845 | $700,000 |
$(-19,894.0)
(-586,460)
kWh
|
- | - |
$43,815
-
MMBtu
|
$32,400 | - | $157,524 | |
05 | 2.4133: Use most efficient type of electric motors | $4,023 | $54,672 |
$1,461
4,396
kWh
|
$2,301
-
kW-mo/yr
|
$261 | - | - | - | - | |
06 | 2.3137: Use power during off-peak periods | $38,560 | - | - | - | - | - | - | $38,560 | - | |
TOTAL RECOMMENDED | $275,450 | $768,832 |
$(-14,840.0)
(-463,072)
kWh
|
$8,045
-
kW-mo/yr
|
$821 |
$43,815
-
MMBtu
|
$32,400 | $38,560 | $166,649 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Fuel Oil #2 Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs