Assessment Year | 1999 |
---|---|
Principal Product | Custom Mixed Rubber |
NAICS |
n/a
|
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
153,000
ft2
|
Annual Production | 86,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $367,272 | 11,511,430 |
kWh
|
$0.032 |
Electricity Fees | $41,790 | - |
|
- |
Natural Gas | $61,415 | 10,967 |
MMBtu
|
$5.60 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $85,958 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,195 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $31,943 | - | - |
$24,060
-
kW-mo/yr
|
$7,883 | - | - | - | |
02 | 2.2511: Insulate bare equipment | $13,210 | $19,500 | - | - | - |
$13,210
-
MMBtu
|
- | - | |
03 | 3.4155: Meter waste water | $408 | $450 | - | - | - | - |
$408
-
Tgal
|
- | |
04 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $2,465 | $1,280 |
$2,325
41,032
kWh
|
- | $140 | - | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,487 | $890 |
$1,403
24,912
kWh
|
- | $84 | - | - | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $1,985 | $660 |
$1,873
33,118
kWh
|
- | $112 | - | - | - | |
07 | 2.7235: Install fossil fuel make-up air unit | $2,110 | $5,500 | - | - | - |
$2,110
-
MMBtu
|
- | - | |
08 | 2.7132: Install timers on light switches in little used areas | $29,350 | $5,500 |
$27,689
489,449
kWh
|
- | $1,661 | - | - | - | |
09 | 3.4151: Minimize water usage | $3,000 | $10,100 | - | - | - | - | - |
$3,000
-
Tgal
|
|
TOTAL RECOMMENDED | $85,958 | $43,880 |
$33,290
588,511
kWh
|
$24,060
-
kW-mo/yr
|
$9,880 |
$15,320
-
MMBtu
|
$408
-
Tgal
|
$3,000
-
Tgal
|
||
TOTAL IMPLEMENTED | $15,195 | $20,160 |
$1,873
33,118
kWh
|
- | $112 |
$13,210
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs