Assessment Year | 1998 |
---|---|
Principal Product | hand tools |
NAICS |
n/a
|
SIC | 3421: Cutlery |
Sales Range | $50 M to 100M |
# of Employees | 320 |
Plant Area |
250,000
ft2
|
Annual Production | 5,800,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $605,580 | 18,924,385 |
kWh
|
$0.032 |
Electricity Demand | $276,145 | 24,959 |
kW-mo/yr
|
$11.06 |
Electricity Fees | $52,903 | - |
|
- |
Natural Gas | $112,056 | 24,259 |
MMBtu
|
$4.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $172,665 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,260 | $3,100 |
$17,226
538,394
kWh
|
- | $1,034 | - | - | - | - | |
02 | 2.2514: Cover open tanks | $21,415 | $6,174 |
$11,023
436,694
kWh
|
$9,179
-
kW-mo/yr
|
$1,213 | - | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $6,874 | $52,766 |
$3,533
139,801
kWh
|
$2,952
-
kW-mo/yr
|
$389 | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,505 | $3,933 |
$774
30,481
kWh
|
$646
-
kW-mo/yr
|
$85 | - | - | - | - | |
05 | 2.2136: Install / repair insulation on steam lines | $1,004 | $413 | - | - | - |
$1,004
-
MMBtu
|
- | - | - | |
06 | 3.5311: Recover and reuse waste material | $16,208 | $38,860 | - | - | - | - |
$3,028
-
lb
|
$13,180 | - | |
07 | 3.5316: Contract a wood pallet recycling company | $2,099 | - | - | - | - | - |
$699
-
lb
|
$1,400 | - | |
08 | 4.111: Add equipment/ operators to reduce production bottleneck | $105,300 | $120,000 | - | - | - | - | - | - | $105,300 | |
TOTAL RECOMMENDED | $172,665 | $225,246 |
$32,556
1,145,370
kWh
|
$12,777
-
kW-mo/yr
|
$2,721 |
$1,004
-
MMBtu
|
$3,727
-
lb
|
$14,580 | $105,300 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs