Assessment Year | 1998 |
---|---|
Principal Product | Manufactured Homes |
NAICS |
n/a
|
SIC | 2451: Mobile Homes |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
120,000
ft2
|
Annual Production | 2,525
pieces
|
Production Hrs. Annual | 2,146
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $64,207 | 1,269,050 |
kWh
|
$0.051 |
Electricity Demand | $25,646 | 3,559 |
kW-mo/yr
|
$7.21 |
Electricity Fees | $20,339 | - |
|
- |
Natural Gas | $17,540 | 2,288 |
MMBtu
|
$7.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $96,190 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $90,429 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,643 | $1,450 |
$5,064
99,941
kWh
|
$4,033
-
kW-mo/yr
|
$546 | - | - | - | - | |
02 | 2.4314: Use synthetic lubricant | $1,637 | - |
$911
17,878
kWh
|
$726
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $256 | $240 |
$144
2,931
kWh
|
$112
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,147 | $5,060 |
$3,006
82,649
kWh
|
- | $141 | - | - | - | - | |
05 | 3.5311: Recover and reuse waste material | $1,440 | - | - | - | - |
$1,440
-
lb
|
- | - | - | |
06 | 4.213: Purchase material from supplier in customized packaging | $25,130 | - | - | - | - |
$288
-
lb
|
- | $24,842 | - | |
07 | 3.5311: Recover and reuse waste material | $50,616 | $60,000 | - | - | - | - | $(-24,936.0) | $78,156 | $(-2,604.0) | |
08 | 2.6242: Minimize operation of equipment maintained in standby condition | $4,321 | $5,000 |
$2,277
45,135
kWh
|
$1,816
-
kW-mo/yr
|
$228 | - | - | - | - | |
TOTAL RECOMMENDED | $96,190 | $71,750 |
$11,402
248,534
kWh
|
$6,687
-
kW-mo/yr
|
$915 |
$1,728
-
lb
|
$(-24,936.0) | $102,998 | $(-2,604.0) | ||
TOTAL IMPLEMENTED | $90,429 | $66,750 |
$9,125
203,399
kWh
|
$4,871
-
kW-mo/yr
|
$687 |
$288
-
lb
|
$(-24,936.0) | $102,998 | $(-2,604.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs