Assessment Year | 1997 |
---|---|
Principal Product | Laminated Wood |
NAICS |
n/a
|
SIC | 2493: Reconstituted Wood Products |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
65,000
ft2
|
Annual Production | 50,000
thousand feet
|
Production Hrs. Annual | 6,400
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $83,714 | 3,547,186 |
kWh
|
$0.024 |
Electricity Demand | $107,528 | 6,773 |
kW-mo/yr
|
$15.88 |
Electricity Fees | $9,320 | - |
|
- |
Natural Gas | $141,863 | 24,234 |
MMBtu
|
$5.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $118,910 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,860 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $57,241 | $66,640 | - | - | - | - |
$(-5,020.0)
-
MMBtu
|
- | - | $62,261 | - | |
02 | 2.8114: Change rate schedules or other changes in utility service | $11,202 | - | - | - | - | - | - | - | - | $11,202 | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,860 | $300 |
$795
33,705
kWh
|
$963
-
kW-mo/yr
|
$102 | - | - | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,350 | $11,600 |
$1,435
60,668
kWh
|
$1,727
-
kW-mo/yr
|
$188 | - | - | - | - | - | - | |
05 | 2.1223: Install smaller boiler (increase high fire duty cycle) | $2,485 | - | - | - | - |
$3,385
-
MMBtu
|
- | - | - | $(-900.0) | - | |
06 | 2.7314: Reduce ventilation air | $11,330 | $10,500 |
$8,360
148,007
kWh
|
- | - |
$2,970
-
MMBtu
|
- | - | - | - | - | |
07 | 4.432: Cross-train personnel to avoid lost time | $3,460 | $1,000 |
$676
28,722
kWh
|
$818
-
kW-mo/yr
|
$91 | - | - | - | $1,875 | - | - | |
08 | 3.4114: Replace city water with recycled water via cooling tower | $27,982 | $2,100 |
$(-388.0)
(-7,034)
kWh
|
- | - | - | - |
$28,870
-
Tgal
|
- | - | $(-500.0) | |
TOTAL RECOMMENDED | $118,910 | $92,140 |
$10,878
264,068
kWh
|
$3,508
-
kW-mo/yr
|
$381 |
$6,355
-
MMBtu
|
$(-5,020.0)
-
MMBtu
|
$28,870
-
Tgal
|
$1,875 | $72,563 | $(-500.0) | ||
TOTAL IMPLEMENTED | $1,860 | $300 |
$795
33,705
kWh
|
$963
-
kW-mo/yr
|
$102 | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs