Assessment Year | 1997 |
---|---|
Principal Product | Aggregate Stone |
NAICS |
n/a
|
SIC | 3281: Cut Stone and Stone Products |
Sales Range | $10 M to 50M |
# of Employees | 66 |
Plant Area |
n/a
|
Annual Production | 1,800,000
ton
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $156,563 | 3,914,127 |
kWh
|
$0.040 |
Electricity Demand | $221,919 | 20,065 |
kW-mo/yr
|
$11.06 |
Electricity Fees | $22,709 | - |
|
- |
LPG | $2,500 | 192 |
MMBtu
|
$13.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $39,293 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,600 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8112: Combine utility meters | $8,120 | $18,860 | - | - | - | - | $8,120 | - | |
02 | 2.4133: Use most efficient type of electric motors | $426 | $6,227 |
$196
4,982
kWh
|
$206
-
kW-mo/yr
|
$24 | - | - | - | |
03 | 2.6218: Turn off equipment when not in use | $5,260 | $4,000 |
$2,417
60,375
kWh
|
$2,545
-
kW-mo/yr
|
$298 | - | - | - | |
04 | 2.6218: Turn off equipment when not in use | $7,317 | $3,510 |
$3,357
83,822
kWh
|
$3,546
-
kW-mo/yr
|
$414 | - | - | - | |
05 | 3.5112: Reprocess spent oils on site for re-use | $2,625 | $3,500 | - | - | - | - | - | $2,625 | |
06 | 2.5124: Use gravity feeds wherever possible | $3,425 | $5,130 |
$1,572
39,273
kWh
|
$1,659
-
kW-mo/yr
|
$194 | - | - | - | |
07 | 2.5124: Use gravity feeds wherever possible | $2,568 | $14,250 |
$1,182
29,308
kWh
|
$1,241
-
kW-mo/yr
|
$145 | - | - | - | |
08 | 2.7122: Disconnect ballasts | $552 | $84 |
$253
6,448
kWh
|
$266
-
kW-mo/yr
|
$33 | - | - | - | |
09 | 3.7311: Maintain machines to reduce leaks | $6,500 | $5,000 | - | - | - | - | - | $6,500 | |
10 | 3.5112: Reprocess spent oils on site for re-use | $2,500 | $9,400 | - | - | - |
$2,500
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $39,293 | $69,961 |
$8,977
224,208
kWh
|
$9,463
-
kW-mo/yr
|
$1,108 |
$2,500
-
MMBtu
|
$8,120 | $9,125 | ||
TOTAL IMPLEMENTED | $27,600 | $47,211 |
$7,795
194,900
kWh
|
$8,222
-
kW-mo/yr
|
$963 |
$2,500
-
MMBtu
|
$8,120 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs