Assessment Year | 1996 |
---|---|
Principal Product | sweatshirts |
NAICS |
n/a
|
SIC | 2322: Men's and Boys' Underwear and Nightwear |
Sales Range | $50 M to 100M |
# of Employees | 500 |
Plant Area |
80,000
ft2
|
Annual Production | 15,600,000
pieces
|
Production Hrs. Annual | 8,200
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,940 | 2,044,256 |
kWh
|
$0.048 |
Electricity Demand | $20,176 | 5,765 |
kW-mo/yr
|
$3.50 |
Electricity Fees | $4,760 | - |
|
- |
Natural Gas | $20,639 | 3,667 |
MMBtu
|
$5.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,820 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,730 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $12,080 | $2,600 |
$8,596
177,608
kWh
|
- | $344 |
$3,140
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,650 | $34,000 |
$5,745
118,699
kWh
|
$2,562
-
kW-mo/yr
|
$343 | - | |
03 | 2.4235: Remove or close off unneeded compressed air lines | $10,750 | $400 |
$9,404
194,314
kWh
|
$924
-
kW-mo/yr
|
$422 | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $720 | $3,730 |
$468
9,672
kWh
|
$210
-
kW-mo/yr
|
$42 | - | |
05 | 2.3212: Optimize plant power factor | $6,620 | $11,100 | - |
$6,370
-
kW-mo/yr
|
$250 | - | |
TOTAL RECOMMENDED | $38,820 | $51,830 |
$24,213
500,293
kWh
|
$10,066
-
kW-mo/yr
|
$1,401 |
$3,140
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,730 | $36,600 |
$14,341
296,307
kWh
|
$2,562
-
kW-mo/yr
|
$687 |
$3,140
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs