| Assessment Year | 1995 |
|---|---|
| Principal Product | Conduit Seal |
| NAICS |
n/a
|
| SIC | 3568: Mechanical Power Transmission Equipment, Not Elsewhere Classified |
| Sales Range | $500 k to 1M |
| # of Employees | 7 |
| Plant Area |
30,000
ft2
|
| Annual Production | 1,000,000
lb
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $50,993 | 454,279 |
kWh
|
$0.11 |
| Natural Gas | $731 | 120 |
MMBtu
|
$6.09 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,575 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,350 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $6,700 | - |
$6,700
-
kWh
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $670 | $1,450 |
$670
35,170
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $510 | $720 |
$510
4,689
kWh
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,840 | $200 |
$2,840
25,205
kWh
|
- | |
| 05 | 3.1191: Change procedures / equipment / operating conditions | $20,855 | $66,000 |
$5,205
46,600
kWh
|
$15,650
-
lb
|
|
| TOTAL RECOMMENDED | $31,575 | $68,370 |
$15,925
111,664
kWh
|
$15,650
-
lb
|
||
| TOTAL IMPLEMENTED | $3,350 | $920 |
$3,350
29,894
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs