Assessment Year | 1995 |
---|---|
Principal Product | Woven Cloth |
NAICS |
n/a
|
SIC | 2211: Broadwoven Fabric Mills, Cotton |
Sales Range | $10 M to 50M |
# of Employees | 350 |
Plant Area |
100,000
ft2
|
Annual Production | 134,181,360
thousand feet
|
Production Hrs. Annual | 6,336
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,086,517 | 27,522,861 |
kWh
|
$0.039 |
Natural Gas | $45,634 | 18,926 |
MMBtu
|
$2.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $152,390 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $12,205 | $26,520 |
$12,205
315,944
kWh
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,668 | $2,683 |
$1,668
48,359
kWh
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $4,516 | $200 |
$4,516
125,440
kWh
|
- | - | |
04 | 2.1321: Replace fossil fuel equipment with electrical equipment | $134,001 | $144,000 | - |
$31,401
-
MMBtu
|
$102,600 | |
TOTAL RECOMMENDED | $152,390 | $173,403 |
$18,389
489,743
kWh
|
$31,401
-
MMBtu
|
$102,600 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs