ITAC Assessment: GT0567
ITAC logo
ITAC Assessment: GT0567
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Velvet
NAICS
n/a
SIC 2221: Broadwoven Fabric Mills, Manmade Fiber and Silk
Sales Range $10
M
to 50
M
# of Employees 459
Plant Area 150,000
ft2
Annual Production 15,510
thousand feet
Production Hrs. Annual 8,760
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $627,076 13,909,144
kWh
Natural Gas $400,305 131,329
MMBtu
LPG $9,492 723
MMBtu
Fuel Oil #6 $25,532 7,780
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $311,720 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $294,220

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $14,700 $900 - $14,700
-
MMBtu
02 2.2414: Use waste heat from hot flue gases to preheat $17,500 $16,500 - $17,500
-
MMBtu
03 2.7111: Reduce illumination to minimum necessary levels $1,990 $145 $1,990
49,824
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $18,340 $38,280 $18,340
419,695
kWh
-
05 2.4133: Use most efficient type of electric motors $6,420 $45,060 $6,420
180,539
kWh
-
06 2.2135: Repair and eliminate steam leaks $6,860 $700 - $6,860
-
MMBtu
07 2.1311: Replace electrically-operated equipment with fossil fuel equipment $58,060 $37,200 $58,060
1,006,155
kWh
-
08 2.6218: Turn off equipment when not in use $1,650 - $1,650
12,309
kWh
-
09 3.1191: Change procedures / equipment / operating conditions $186,200 $100,000 $186,200
10,741,501
kWh
-
TOTAL RECOMMENDED $311,720 $238,785 $272,660
12,410,023
kWh
$39,060
-
MMBtu
TOTAL IMPLEMENTED $294,220 $222,285 $272,660
12,410,023
kWh
$21,560
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs