| Assessment Year | 1995 |
|---|---|
| Principal Product | FLour Mixes |
| NAICS |
n/a
|
| SIC | 2041: Flour and Other Grain Mill Products |
| Sales Range | $10 M to 50M |
| # of Employees | 175 |
| Plant Area |
130,000
ft2
|
| Annual Production | 200,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $569,847 | 10,453,107 |
kWh
|
$0.055 |
| Natural Gas | $28,182 | 4,816 |
MMBtu
|
$5.85 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $66,980 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8112: Combine utility meters | $12,690 | $20,000 | - | - | $12,690 | |
| 02 | 2.3137: Use power during off-peak periods | $28,400 | - |
$28,400
-
kWh
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $12,210 | $88,380 |
$12,210
230,070
kWh
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,250 | $1,720 |
$2,250
44,549
kWh
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,030 | $9,070 |
$3,030
37,808
kWh
|
- | - | |
| 06 | 2.7134: Use photocell controls | $1,000 | $240 |
$1,000
14,654
kWh
|
- | - | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $1,040 | - |
$1,040
20,809
kWh
|
- | - | |
| 08 | 2.7124: Make a practice of turning off lights when not needed | $520 | $350 |
$520
10,258
kWh
|
- | - | |
| 09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,660 | - |
$1,660
48,066
kWh
|
- | - | |
| 10 | 2.2437: Recover waste heat from equipment | $4,180 | $2,500 | - |
$4,180
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $66,980 | $122,260 |
$50,110
406,214
kWh
|
$4,180
-
MMBtu
|
$12,690 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs