Assessment Year | 1995 |
---|---|
Principal Product | Recycled Polyethylene Plastic Flakes |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | less than $500 k |
# of Employees | 45 |
Plant Area |
60,000
ft2
|
Annual Production | 16,000,000
lb
|
Production Hrs. Annual | 5,500
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $59,610 | 876,612 |
kWh
|
$0.068 |
Natural Gas | $16,818 | 2,802 |
MMBtu
|
$6.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,567 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $2,325 | $4,100 | n/a |
$2,325
34,291
kWh
|
- |
02 | 2.2136: Install / repair insulation on steam lines | $342 | $230 | n/a | - |
$342
-
MMBtu
|
03 | 2.2135: Repair and eliminate steam leaks | $70 | $45 | n/a | - |
$70
-
MMBtu
|
04 | 2.1224: Replace boiler | $3,542 | $7,100 | n/a | - |
$3,542
-
MMBtu
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,288 | $6,243 | n/a |
$3,288
48,359
kWh
|
- |
TOTAL RECOMMENDED | $9,567 | $17,718 |
$5,613
82,650
kWh
|
$3,954
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs