| Assessment Year | 1994 |
|---|---|
| Principal Product | Propane Cylinders |
| NAICS |
n/a
|
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
110,000
ft2
|
| Annual Production | 1,225,000
pieces
|
| Production Hrs. Annual | 7,700
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $387,121 | 9,699,004 |
kWh
|
$0.040 |
| Natural Gas | $230,543 | 70,437 |
MMBtu
|
$3.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $55,010 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2425: Use flue gases to heat process or service water | $47,900 | $33,800 | - |
$47,900
-
MMBtu
|
|
| 02 | 2.2437: Recover waste heat from equipment | $2,580 | $5,030 |
$(-80.0)
(-2,931)
kWh
|
$2,660
-
MMBtu
|
|
| 03 | 2.1133: Adjust burners for efficient operation | $3,540 | $500 | - |
$3,540
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $700 | $4,140 |
$700
28,136
kWh
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $290 | $450 |
$290
11,723
kWh
|
- | |
| TOTAL RECOMMENDED | $55,010 | $43,920 |
$910
36,928
kWh
|
$54,100
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs