Assessment Year | 1994 |
---|---|
Principal Product | Fashion Accessory Pillows |
NAICS |
n/a
|
SIC | 2392: House furnishing, Except Curtains and Draperies |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
100,000
ft2
|
Annual Production | 2,400,000
pieces
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $80,697 | 736,811 |
kWh
|
$0.11 |
Natural Gas | $21,627 | 2,909 |
MMBtu
|
$7.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,545 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,545 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $5,525 | $1,200 | - |
$5,525
-
MMBtu
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,210 | $780 |
$1,210
11,137
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $715 | $50 |
$715
6,448
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,760 | $24,565 |
$8,760
80,305
kWh
|
- | |
05 | 2.7134: Use photocell controls | $335 | $200 |
$335
2,931
kWh
|
- | |
TOTAL RECOMMENDED | $16,545 | $26,795 |
$11,020
100,821
kWh
|
$5,525
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,545 | $26,795 |
$11,020
100,821
kWh
|
$5,525
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs