| Assessment Year | 1994 |
|---|---|
| Principal Product | Dyed Fabric |
| NAICS |
n/a
|
| SIC | 2211: Broadwoven Fabric Mills, Cotton |
| Sales Range | $10 M to 50M |
| # of Employees | 175 |
| Plant Area |
400,000
ft2
|
| Annual Production | 7,300,000
lb
|
| Production Hrs. Annual | 6,732
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $205,605 | 3,111,079 |
kWh
|
$0.066 |
| Natural Gas | $473,990 | 124,983 |
MMBtu
|
$3.79 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $96,485 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,300 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,860 | $14,260 |
$4,860
118,699
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,190 | $35,300 |
$7,190
175,850
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $5,215 | $5,215 |
$5,215
127,491
kWh
|
- | |
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $19,600 | $30,000 | - |
$19,600
-
MMBtu
|
|
| 05 | 2.2121: Increase amount of condensate returned | $14,440 | $6,500 | - |
$14,440
-
MMBtu
|
|
| 06 | 2.1221: Replace obsolete burners with more efficient ones | $45,180 | $180,000 | - |
$45,180
-
MMBtu
|
|
| TOTAL RECOMMENDED | $96,485 | $271,275 |
$17,265
422,040
kWh
|
$79,220
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $19,300 | $20,760 |
$4,860
118,699
kWh
|
$14,440
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs