Assessment Year | 1994 |
---|---|
Principal Product | Dyed Fabric |
NAICS |
n/a
|
SIC | 2211: Broadwoven Fabric Mills, Cotton |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
400,000
ft2
|
Annual Production | 7,300,000
lb
|
Production Hrs. Annual | 6,732
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $205,605 | 3,111,079 |
kWh
|
$0.066 |
Natural Gas | $473,990 | 124,983 |
MMBtu
|
$3.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $96,485 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,300 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,860 | $14,260 |
$4,860
118,699
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,190 | $35,300 |
$7,190
175,850
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $5,215 | $5,215 |
$5,215
127,491
kWh
|
- | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $19,600 | $30,000 | - |
$19,600
-
MMBtu
|
|
05 | 2.2121: Increase amount of condensate returned | $14,440 | $6,500 | - |
$14,440
-
MMBtu
|
|
06 | 2.1221: Replace obsolete burners with more efficient ones | $45,180 | $180,000 | - |
$45,180
-
MMBtu
|
|
TOTAL RECOMMENDED | $96,485 | $271,275 |
$17,265
422,040
kWh
|
$79,220
-
MMBtu
|
||
TOTAL IMPLEMENTED | $19,300 | $20,760 |
$4,860
118,699
kWh
|
$14,440
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs