Assessment Year | 1993 |
---|---|
Principal Product | Gas Cutting Apparatus |
NAICS |
n/a
|
SIC | 3548: Electric and Gas Welding and Soldering Equipment |
Sales Range | $10 M to 50M |
# of Employees | 182 |
Plant Area |
60,000
ft2
|
Annual Production | 220,000
pieces
|
Production Hrs. Annual | 6,380
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $183,434 | 2,932,591 |
kWh
|
$0.063 |
Natural Gas | $7,586 | 1,571 |
MMBtu
|
$4.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,535 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,515 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,615 | $6,380 |
$4,615
73,857
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,255 | $9,240 |
$3,255
52,169
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $645 | $1,130 |
$645
10,258
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $1,170 | $1,780 |
$1,170
18,757
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $360 | - |
$360
5,862
kWh
|
|
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $9,590 | $7,800 |
$9,590
-
kWh
|
|
07 | 2.8114: Change rate schedules or other changes in utility service | $18,900 | $300 |
$18,900
-
kWh
|
|
TOTAL RECOMMENDED | $38,535 | $26,630 |
$38,535
160,903
kWh
|
||
TOTAL IMPLEMENTED | $8,515 | $16,750 |
$8,515
136,284
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs