Assessment Year | 1992 |
---|---|
Principal Product | ALLOY CASTINGS |
NAICS |
n/a
|
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $10 M to 50M |
# of Employees | 226 |
Plant Area |
n/a
|
Annual Production | 7,000
ton
|
Production Hrs. Annual | 7,400
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $496,327 | 16,309,789 |
kWh
|
$0.030 |
Natural Gas | $209,212 | 48,747 |
MMBtu
|
$4.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,880 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $390 | $21,630 |
$390
12,896
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $300 | - |
$300
9,965
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $14,770 | $10,000 |
$14,770
485,932
kWh
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $10,180 | $9,000 | - |
$10,180
-
MMBtu
|
|
05 | 2.2414: Use waste heat from hot flue gases to preheat | $9,040 | $5,100 | - |
$9,040
-
MMBtu
|
|
06 | 2.1122: Re-size charging openings or add a movable door on equipment | $200 | $1,015 | - |
$200
-
MMBtu
|
|
TOTAL RECOMMENDED | $34,880 | $46,745 |
$15,460
508,793
kWh
|
$19,420
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs