| Assessment Year | 1991 |
|---|---|
| Principal Product | GRANITE |
| NAICS |
n/a
|
| SIC | 3281: Cut Stone and Stone Products |
| Sales Range | n/a |
| # of Employees | 80 |
| Plant Area |
n/a
|
| Annual Production | 46,000
ton
|
| Production Hrs. Annual | 2,750
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $129,524 | 1,851,407 |
kWh
|
$0.070 |
| Natural Gas | $5,327 | 1,016 |
MMBtu
|
$5.24 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,430 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $91 | $2,090 |
$138
2,052
kWh
|
$(-47.0) | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,340 | $12,780 |
$5,660
80,598
kWh
|
$(-320.0) | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,061 | $10,260 |
$2,061
29,308
kWh
|
- | |
| 04 | 2.3212: Optimize plant power factor | $938 | $2,964 |
$938
13,482
kWh
|
- | |
| TOTAL RECOMMENDED | $8,430 | $28,094 |
$8,797
125,440
kWh
|
$(-367.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs