Assessment Year | 1991 |
---|---|
Principal Product | SNACK CHIPS |
NAICS |
n/a
|
SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 23,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $432,766 | 8,156,507 |
kWh
|
$0.053 |
Natural Gas | $273,380 | 87,795 |
MMBtu
|
$3.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,127 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $9,380 | - | - |
$9,980
-
MMBtu
|
$(-600.0) | |
02 | 3.4154: Eliminate leaks in water lines and valves | $902 | - | - |
$902
-
MMBtu
|
- | |
03 | 2.2121: Increase amount of condensate returned | $10,480 | $3,670 | - |
$10,480
-
MMBtu
|
- | |
04 | 2.2135: Repair and eliminate steam leaks | $2,450 | $425 | - |
$2,450
-
MMBtu
|
- | |
05 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $1,030 | $4,500 | - |
$1,030
-
MMBtu
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $2,350 | $2,570 |
$2,350
135,991
kWh
|
- | - | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,535 | - | - |
$1,835
-
MMBtu
|
$(-300.0) | |
TOTAL RECOMMENDED | $28,127 | $11,165 |
$2,350
135,991
kWh
|
$26,677
-
MMBtu
|
$(-900.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs