| Assessment Year | 1991 |
|---|---|
| Principal Product | RIDGE VENTILATION |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | n/a |
| # of Employees | 20 |
| Plant Area |
n/a
|
| Annual Production | 76,500
pieces
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $27,673 | 283,118 |
kWh
|
$0.098 |
| Natural Gas | $10,320 | 1,780 |
MMBtu
|
$5.80 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,421 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,421 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $429 | - |
$429
4,396
kWh
|
- | |
| 02 | 2.3512: De-energize excess transformer capacity | $562 | $400 |
$562
5,862
kWh
|
- | |
| 03 | 2.2437: Recover waste heat from equipment | $1,645 | $1,500 | - |
$1,645
-
MMBtu
|
|
| 04 | 2.7141: Lower light fixtures in high ceiling areas | $1,170 | $2,400 |
$1,170
12,016
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $317 | $839 |
$317
3,224
kWh
|
- | |
| 06 | 2.4133: Use most efficient type of electric motors | $68 | $563 |
$68
586
kWh
|
- | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $70 | - |
$70
879
kWh
|
- | |
| 08 | 2.7261: Install timers and/or thermostats | $1,160 | $600 | - |
$1,160
-
MMBtu
|
|
| TOTAL RECOMMENDED | $5,421 | $6,302 |
$2,616
26,963
kWh
|
$2,805
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,421 | $6,302 |
$2,616
26,963
kWh
|
$2,805
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs