| Assessment Year | 1990 |
|---|---|
| Principal Product | HEAT SET CARPET YARN |
| NAICS |
n/a
|
| SIC | 2281: Yarn Spinning Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
n/a
|
| Annual Production | 14,250,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $623,828 | 12,514,947 |
kWh
|
$0.050 |
| Natural Gas | $235,289 | 61,109 |
MMBtu
|
$3.85 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $40,444 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $36,630 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,050 | $34,920 |
$20,050
401,817
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,814 | $4,225 |
$3,814
76,495
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $2,615 | $8,720 |
$2,615
52,462
kWh
|
- | |
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,565 | $200 | - |
$6,565
-
MMBtu
|
|
| 05 | 2.6231: Utilize controls to operate equipment only when needed | $5,600 | $5,000 |
$5,600
112,837
kWh
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,800 | $1,000 |
$1,800
36,049
kWh
|
- | |
| TOTAL RECOMMENDED | $40,444 | $54,065 |
$33,879
679,660
kWh
|
$6,565
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $36,630 | $49,840 |
$30,065
603,165
kWh
|
$6,565
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs