| Assessment Year | 1989 |
|---|---|
| Principal Product | PLASTIC CONTAINERS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 73 |
| Plant Area |
n/a
|
| Annual Production | 100,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $535,180 | 11,063,892 |
kWh
|
$0.048 |
| Natural Gas | $26,678 | 6,015 |
MMBtu
|
$4.44 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,101 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,690 | $1,335 |
$1,690
34,877
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,042 | - |
$3,042
62,720
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $900 | $2,470 |
$900
18,464
kWh
|
|
| 04 | 2.7229: Air condition only space necessary | $2,469 | $420 |
$2,469
50,996
kWh
|
|
| TOTAL RECOMMENDED | $8,101 | $4,225 |
$8,101
167,057
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs