| Assessment Year | 1989 |
|---|---|
| Principal Product | MEAT PROCESSING & PACKAGING |
| NAICS |
n/a
|
| SIC | 2011: Meat Packing Plants |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
n/a
|
| Annual Production | 75,000,000
lb
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $274,623 | 4,487,104 |
kWh
|
$0.061 |
| Natural Gas | $239,464 | 74,760 |
MMBtu
|
$3.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,439 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,369 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,468 | $2,940 |
$2,468
46,893
kWh
|
- | |
| 02 | 2.2121: Increase amount of condensate returned | $12,750 | $27,000 | - |
$12,750
-
MMBtu
|
|
| 03 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $3,740 | $15,000 | - |
$3,740
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,330 | $7,990 |
$3,330
63,306
kWh
|
- | |
| 05 | 2.2122: Install / repair insulation on condensate lines | $1,623 | $2,035 | - |
$1,623
-
MMBtu
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $528 | - |
$528
9,965
kWh
|
- | |
| TOTAL RECOMMENDED | $24,439 | $54,965 |
$6,326
120,164
kWh
|
$18,113
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $17,369 | $31,975 |
$2,996
56,858
kWh
|
$14,373
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs